Index

Data Type OcaLevelMeterLaw

Enumeration of level meter laws.

Properties

OcaEnumItem VU = 1

Generic VU-style meter, characteristics defined by device.

OcaEnumItem StandardVU = 2

Classic VU meter per ANSI C16.5-1942, British Standard BS 6840, and IEC 60268-17.

OcaEnumItem PPM1 = 3

IEC 60268-10 Peak Programme Meter, type I (Germany).

OcaEnumItem PPM2 = 4

IEC 60268-10 Peak Programme Meter, type II (BBC).

OcaEnumItem LKFS = 5

Loudness meter as defined by ITU BS1770.

OcaEnumItem RMS = 6

Simple RMS meter

OcaEnumItem Peak = 7

Simple peak meter

OcaEnumItem ProprietaryValueBase = 128

Proprietery classes shall add values of this value or greater. Values 0 to 127 are reserved.

OCP.1 Encoding

Basic typeByte Length
OcaEnumItem1